Measurement chain

Power & noise

Track signal power, connection limits, and cascaded noise through cables, pads, couplers, and amplifiers.

Source and measurement bandwidth

Matched ports at one operating frequency. Gains and losses are small-signal values. Power is one CW tone; output limits apply to that estimated signal power. Compression, reflections, and peak-envelope limits require separate checks.

Measurement chain

Blank gain or loss means 0 dB (unity). Noise figure and temperatures are required; a blank limit means no limit. Order stages from the source to the receiver. Use a passive stage for cable loss, a pad, or a coupler branch. Name its output connection (for example, “DUT input”). Limits are optional, in dBm at that output.

Power at each connection

ConnectionGain / lossSignalOutput limitHeadroom

Noise through the same chain

Noise figure is referenced to 290 K. Passive-stage noise uses its physical temperature; amplifier noise figure is an input specification. Output noise uses the source temperature and equivalent noise bandwidth entered above.

Stage outputStage NFCumulative NFOutput noise

Added noise referred to the chain input

Model and reference

Friis cascade: F = 1 + Σ (Fᵢ − 1)/Gbeforeᵢ, using linear power gain and noise factor. A passive loss L at temperature T has F = 1 + (L − 1)T/290 K. Noise output = kB[Tsource + 290 K(F − 1)]Gtotal.

Assumes matched stages, independent noise, and gain/noise figure constant over the chosen bandwidth. Coupler loss refers to the selected branch with other ports terminated. A filter's nominal bandwidth may differ from its equivalent noise bandwidth.

Keysight: noise figure measurements